Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : HNMC
Model Number : MCSP01
Place of Origin : China
MOQ : 1
Price : Negotiable
Payment Terms : L/C, T/T, Western Union
Supply Ability : 500 sets per month
Delivery Time : 15-30 days
Packaging Details : Carton package
Accuracy : 0.2, 0.5
Current range : 10-300A (clamp mode,optional)
Voltage range : 80-288V
GPS/GPRS : Available for option
Application : Filed Testing
Functions : Meter error, dial test....etc
Portable Single Phase Reference Standard Meter MCSP01
1) 3.5" LCD display
2) Accuracy class: 0.2 or 0.5 (clamp mode)
3) Measuring range: 80V-288V/clamp 10A, 50A, 60A, 100A, 300A optional
4) Power & Energy test, Demand test, Error test, Dial test
5) RS232 communication with PC to upload the test data
6) GPS/GPRS module (optional)
7) DLMS reading (optional)
Technical Index
Current Measurement | |
Range | clamp on CT: 10A, 50A, 60A, 100A, 300A, etc… optional |
Accuracy | 0.2 or 0.5 class |
Voltage measurement | |
Range | 80-312V |
Accuracy | 0.2 |
Frequency measurement | |
Range | 45-65HZ |
Error | ≤ 0.02HZ |
Phase angle measurement | |
Range | 0-360 deg. |
Error | ≤0.1 deg. |
Other parameters | |
Power supply | 240V±30% |
Power Consumption | less than 2VA in current circuit and less than 8VA in voltage circuit |
Features
1) Test all kinds of electronics/electromechanical single phase meter at site
2) Test and display of basic error, voltage, current, power, power factor, energy, harmonics, etc
3) Dial test / demand test
4) PC software for uploading test data then analyze then generate report
5) Alpha numeric keyboard
6) Optical sensor with clamp or attaching disc to hold & count LED/LCD signal pulse
7) Snap switch to be used as an alternative of scanner/sensor head
8) Clamp-on CT with electronic compensation
9) Display error and store total energy including harmonics
10) LCD display
11) High Resolution Display
12) Two kinds of operation modes (auto & manual)
13) Indication with the display under below conditions:
a. over current (more than 120%)
b. over voltage (more than 130%)
c. low voltage (less than 70%)
14) Store 200 & more test results
15) Interface to connect external printer
16) PC management software of uploaded the test records
Function Menu Interface:
1) Meter Parameter Setting 2) Error Test 3) THD 4) Data Save & Inquiry
5) System setting 6) CT ratio test 7) Demand test 8) Dial test 9) others
![]() |
3.5" LCD Display Portable Meter Test Equipment GPS Module Single Phase RSM Images |